Single sampling plans for normal inspection (Table II-A)
Rows are code letters with their sample sizes; columns are AQLs. Each cell gives Ac and Re. Scroll sideways to see all 26 AQLs.
| Code letterSample size | Acceptable quality levels (normal inspection) | |||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.010Ac Re | 0.015Ac Re | 0.025Ac Re | 0.040Ac Re | 0.065Ac Re | 0.10Ac Re | 0.15Ac Re | 0.25Ac Re | 0.40Ac Re | 0.65Ac Re | 1.0Ac Re | 1.5Ac Re | 2.5Ac Re | 4.0Ac Re | 6.5Ac Re | 10Ac Re | 15Ac Re | 25Ac Re | 40Ac Re | 65Ac Re | 100Ac Re | 150Ac Re | 250Ac Re | 400Ac Re | 650Ac Re | 1000Ac Re | |
| A2 | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | 0 1 | ↓ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | 30 31 |
| B3 | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | 0 1 | ↑ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | 30 31 | 44 45 |
| C5 | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | 0 1 | ↑ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | 30 31 | 44 45 | ↑ |
| D8 | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | 0 1 | ↑ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | 30 31 | 44 45 | ↑ | ↑ |
| E13 | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | 0 1 | ↑ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | 30 31 | 44 45 | ↑ | ↑ | ↑ |
| F20 | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | 0 1 | ↑ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ |
| G32 | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | 0 1 | ↑ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ |
| H50 | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | 0 1 | ↑ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ |
| J80 | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | 0 1 | ↑ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ |
| K125 | ↓ | ↓ | ↓ | ↓ | ↓ | 0 1 | ↑ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ |
| L200 | ↓ | ↓ | ↓ | ↓ | 0 1 | ↑ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ |
| M315 | ↓ | ↓ | ↓ | 0 1 | ↑ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ |
| N500 | ↓ | ↓ | 0 1 | ↑ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ |
| P800 | ↓ | 0 1 | ↑ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ |
| Q1,250 | 0 1 | ↑ | ↓ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ |
| R2,000 | ↑ | ↑ | 1 2 | 2 3 | 3 4 | 5 6 | 7 8 | 10 11 | 14 15 | 21 22 | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ | ↑ |
- ↓use the first sampling plan below the arrow
- ↑use the first sampling plan above the arrow
- Ac = acceptance number
- Re = rejection number
If the sample size equals or exceeds the lot or batch size, do 100 percent inspection.
AQLs of 10 or less may be read as percent defective or as defects per hundred units; AQLs above 10 are defects per hundred units only (MIL-STD-105E, 4.4.3).
Sample size code letters (Table I) · AQL sampling calculator
Source and limits
Values on this site are transcribed from MIL-STD-105E, Sampling Procedures and Tables for Inspection by Attributes (U.S. Department of Defense, 10 May 1989), Tables I and II-A. Every cell was read from the page scans and then compared by script with a second, separately keyed copy of the tables.
This is a reference tool. It covers single sampling under normal inspection only — not tightened or reduced inspection, and not double or multiple sampling. It has not been compared cell by cell with the current paid editions of ANSI/ASQ Z1.4 or ISO 2859-1. The standard named in your contract or purchase order, in the edition it names, is what governs.